Laboratory accuracy. Wherever you go. The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05 percent + 0.3degrees Celsius) in a rugged, handheld test tool. A dual input thermomoeter, 60 Hz noise rejection.

{{ section.title }}

{{ content.title }}

{{ content.title }}

{{ v }}

{{ content.title }}

  • {{v.name}} : {{v.value}}

{{ content.title }}

{{ content.title }}

360 Images

Specifications

  • Accuracy : Above -100 °C: J, K, T, E, and N-type: ±[0.05% + 0.3°C], R and S-type: ±[0.05% + 0.4°C]; Below -100 °C: J, K, E, and N-types: ±[0.20% + 0.3°C], T-type: ±[0.50% + 0.3°C]
  • Application : Microprocessor-based, digital thermometer designed to use external J-, K-, T-, and E type thermocouples (temperature probes) as temperature sensors
  • Brand Name : Fluke
  • Detector type : Thermocouple
  • Display : 0.1 °C / °F / K <1000°; 1.0 °C / °F / K =1000°
  • Safety Rating : Overvoltage category: CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2; Agency approvals: CE, CSA, TÜV (pending)
  • Standard : Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2; Agency approvals CE, CSA, TÜV (pending)
  • Temperature Range : J-type: -210 °C to 1200 °C; K-type: -200 °C to 1372 °C; T-type: -250 °C to 400 °C; E-type: -150 °C to 1000 °C; N-type: -200 °C to 1300 °C; R and S-type: 0 °C to 1767 °C
  • Type : Digital Thermometer
  • Category : Digital Thermometers
  • Brand : Fluke
Compare

Have a question about this product? Chat with an expert!

DUAL INPUT THRMTR 60HZ NOISE REJECTION

Item Code: 108197
Catalog Number FLUKE-52-2-60HZ
DUAL INPUT THRMTR 60HZ NOISE REJECTION

Images shown may vary from actual product.

Compare

Have a question about this product? Chat with an expert!

Fetching product details


Description

Laboratory accuracy. Wherever you go. The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05 percent + 0.3degrees Celsius) in a rugged, handheld test tool. A dual input thermomoeter, 60 Hz noise rejection.

{{ section.title }}

{{ content.title }}

{{ content.title }}

{{ v }}

{{ content.title }}

  • {{v.name}} : {{v.value}}

{{ content.title }}

{{ content.title }}

360 Images

Specifications

  • Accuracy : Above -100 °C: J, K, T, E, and N-type: ±[0.05% + 0.3°C], R and S-type: ±[0.05% + 0.4°C]; Below -100 °C: J, K, E, and N-types: ±[0.20% + 0.3°C], T-type: ±[0.50% + 0.3°C]
  • Application : Microprocessor-based, digital thermometer designed to use external J-, K-, T-, and E type thermocouples (temperature probes) as temperature sensors
  • Brand Name : Fluke
  • Detector type : Thermocouple
  • Display : 0.1 °C / °F / K <1000°; 1.0 °C / °F / K =1000°
  • Safety Rating : Overvoltage category: CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2; Agency approvals: CE, CSA, TÜV (pending)
  • Standard : Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2; Agency approvals CE, CSA, TÜV (pending)
  • Temperature Range : J-type: -210 °C to 1200 °C; K-type: -200 °C to 1372 °C; T-type: -250 °C to 400 °C; E-type: -150 °C to 1000 °C; N-type: -200 °C to 1300 °C; R and S-type: 0 °C to 1767 °C
  • Type : Digital Thermometer
  • Category : Digital Thermometers
  • Brand : Fluke